Waste Water Analysers

UV-Photo-X Fluorescence Analyser – MODEL 6650B

The ability to monitor the concentration of an analyte in a process stream is critical for accurate and reliable process control. There are many techniques used to determine the analyte concentration of interest. One of the most sensitive sensing techniques is molecular fluorescence. Fluorescence occurs when a molecule absorbs light energy, either ultraviolet or visible, and rapidly emits light, at some longer wavelength. Fluorescence of this type is referred to as Stokes fluorescence. Fluorimetry characterises the excitation and emission properties of the molecular species.

LXT-220

Model LXT-220 Dissolved Oxygen Controller is a robust and versatile instrument for the measurement and process control of dissolved oxygen in a liquid component. Customisable, the Model LXT-220 comes standard with a single 4-20mA current output but can have as many as five. The current output is field selectable and may be expanded to any range within the transmitter’s full operating range. It can also be programmed as reverse acting; for example, a 4-20 mA output for a range of 0 to 10 ppm can be reversed to 10 to 0 ppm.

  • Front panel membrane switches
  • Menu driven backlit display with contrast adjustment
  • Automatic calibration: this allows calibration points to be defined upon initialisation of the transmitter
  • An easy back to factory calibration menu allows the instrument to return to a predetermined factory calibration. The default parameters are: zero electrode offset and –157.5mV/FS slope.
  • 4-20mA current output fully expandable to any range within the transmitter’s full operating range. The output is field selectable and fully programmable. The current output can be configured to be reverse acting
  • Temperature conversion: temperature can be displayed in either Fahrenheit or Celsius. The units can be toggled from one to the other in the field with the conversion calculation performed automatically

Total Organic Carbon Analysers – Series 6700

The Series 6700 covers a complete range of Total Organic Carbon (TOC) Analysers capable of addressing a variety of industrial applications for process and environmental compliance purposes. Depending on the application, TAI can recommend which technique is best suited to continuously detect TOC within your process.

  • Complies with EPA, ASTM and other standard approved methods for continuous TOC analysis
  • NPOC (Non-purgeable organic carbon) analysis
  • TOC-True Analysis (including volatile organics)
  • Rapid response
  • On-board Microsoft Windows CE computer plus paperless chart recorder or Menu driven LCD display
  • Separate electronics and liquid compartments
  • Low maintenance and easy access for service

Dissolved Oxygen Transmitter – LXT-280

Model LXT-280 Transmitter is a robust and versatile instrument for measurement and process control of dissolved oxygen. This instrument is Factory Mutual Approved as intrinsically safe and explosion proof for use in Class I, II and III Divisions 1 Groups A through G hazardous areas. The Model LXT-280 transmitters provide solutions to a variety of liquid analytic applications involving hazardous areas.

  • Magnetic switches located behind a glass window can be activated without having to open the instrument
  • Menu driven backlit display with contrast adjustment
  • Automatic calibration: this allows calibration points to be defined upon initialisation of the transmitter
  • An easy back to factory calibration menu allows the instrument to return to a predetermined factory calibration. The default parameters are: zero electrode offset at 0 ppm or 0% oxygen and -400 mV at full scale
  • 4-20mA current output transmitted on the same 24 VDC power wiring. The current output is fully expandable to any range within the transmitter’s full operating range. The current output can be configured to be reverse acting
  • Temperature conversion: temperature can be displayed in either Fahrenheit or Celsius. The units can be toggled from one to the other in the field with the conversion calculation performed automatically