Instrument Valves and Manifolds

Tube Valve/Heat Actuated Trap valves

TV/HAT (Tube Valve/Heat Actuated Trap) valves are ideal for use in conjunction with tracer tubing and tracing systems using pretraced tubing bundles. These versatile valves are compatible and are made to be used in combination with the TV series valves as well as standard tubing and tubing fittings. TV/HAT valves are ideal for replacing conventional steam traps on winterisation tracing, instrument tracing, condensate return system freeze protection, tracing for processes less than 65 Degree Celsius and other applications requiring in-line flow control based on temperature.

Design Features

  • Compact, low mass for fast response
  • Corrosion resistant – long service life
  • Stainless steel body, fittings, spring and plug
  • Ram-type plug for tight reliable shut-off
  • Eliminates live steam losses
  • Operates in narrow temperature band
  • Downstream actuator for greater sensitivity
  • Unaffected by pressure variations
  • Wide choice of set points
  • Easy to install
  • Operates in any position

Single Sensor Sample Draw Manifold – Model SD-1-N4X

Detcon Model SD-1-N4X is a single sensor sample draw manifold designed to use with many gas detection sensors, including combustible gas, hydrogen sulfide, oxygen and a long list of toxic compounds. The sampling system utilises an internal pump to draw air and gas samples from a remote location and flow the sample across the sensor at a metered flow rate. In use, the sample draw method allows for remote calibration and routine maintenance without exposing maintenance personnel to dangerous or difficult to access sampling areas. Sampling time is a function of the distance between the sample point and the sample draw manifold. Detcon Model SD- 1-N4X is housed in a NEMA 4 weatherproof enclosure and is suitable for installation in outdoor locations. The non-hazardous area rating allows for installation with a minimum distance to the sample point, which decreases delays in real time sampling.

Design Features

  • Power input and flow fault LED indicators
  • Flow fault fail-safe supervision
  • In-line moisture filter
  • Sample pump service life > 3-5 years

Single Sensor Sample Draw Manifold – Model SD-1-N7

Detcon Model SD-1-N7 is a single sensor sample draw manifold designed to use with many gas detection sensors, including combustible gas, hydrogen sulfide, oxygen and a long list of toxic compounds. The sampling system utilises an internal pump to draw air and gas samples from a remote location and flow the sample across the sensor at a metered flow rate. In use, the sample draw method allows for remote calibration and routine maintenance without exposing maintenance personnel to dangerous or difficult to access sampling areas. Sampling time is a function of the distance between the sample point and the sample draw manifold. Detcon Model SD-1-N7 is housed in a NEMA 7 explosion proof enclosure and is suitable for installation in hazardous locations: Class I; Division 1; Group C and D. The hazardous area rating allows for installation with a minimum distance to the sample point, which decreases delays in real time sampling.

Design Features

  • Input/output in-line flame propagation barriers
  • Power input and flow fault LED indicators
  • Flow fault fail-safe supervision
  • In-line sample input moisture filter